Compact Once-through Steam Boiler

OT-350Gi

A smaller footprint,
a reliable steam supply.

350 kg/hr equivalent evaporation, a color HMI 2.0 and fast startup for production sites that need reliable steam, intuitive operation and flexible expansion.

OT-350Gi Gas-fired Steam Boilers— front view
Rated evaporation350kg/hr
Max. working pressure10kg/cm²
Max. efficiency90%
Time to steam4–5minutes

Highlights

Used daily. Simple to run.

The OT-350Gi combines startup, monitoring and safety controls in a clear interface for limited spaces, changing loads and long production runs.

  1. 01Fast Startup

    Steam about 4–5 minutes after ignition.

  2. 02Saves space

    Compact once-through design, heating surface 5.9 m².

  3. 03HMI 2.0

    Colour touchscreen that logs operation and every fault.

  4. 04Regulations

    Under current rules, no operator licence or periodic inspection required.

  5. 05Optional economiser

    Boiler efficiency 88%, up to 90% with an economiser.

  6. 06Safety controls

    Safety valve 25 A, with full safety devices and controls.

Interface and details

OT-350Gi Specifications

The economizer recovers flue-gas heat to reduce fuel use. Actual savings depend on load and operating conditions.

SpecStandardWith economizer
Rated evaporation350 kg/hr
Actual evaporation291 kg/hr
Heat output188,650 kcal/hr
Efficiency88%90%
Fuel consumptionLNG 22.1 Nm³/hr
LPG 17.9 kg/hr
LNG 21.2 Nm³/hr
LPG 17.5 kg/hr
Power1.2 kW
Fuel inlet25 A
Flue size200 mm
Feedwater inlet20 A
Steam outlet25 A
Blowdown25 A
Safety valve25 A
Heating surface5.9 m²
DimensionsW750 × D1,300 × H2,000 mmW750 × D1,370 × H2,000 mm
Weight780 kg
Test conditions & notes
  1. Actual evaporation is based on feedwater at 15°C and saturated steam at 0.49 MPa.
  2. Boiler efficiency is calculated by the JIS B 8222-1993 heat-loss method. Efficiency tolerance: ±1%; combustion capacity tolerance: ±3.5%.
  3. Fuel consumption is calculated using the specified lower heating value. Actual gas heating value and supply pressure affect the result.
  4. Gas piping must maintain adequate pressure while the boiler and other equipment operate. Supply pressure range: 0.03–0.3 MPa.
  5. With an economizer, a feedwater temperature of at least 50°C is recommended.
  6. Specifications may change as products improve. Refer to the latest technical information from Chuang Ting for final selection.

Check whether OT-350Gi suits your site.

Share your connected equipment, steam demand, operating hours and site conditions so our engineers can confirm capacity and system configuration.

Call us · Kaohsiung headquarters+886-7-787-2258