Compact Once-through Steam Boiler

OT-500Gi

Steady output,
sized to production.

500 kg/hr equivalent evaporation, with intuitive controls, fast startup and parallel operation for reliable continuous production.

OT-500Gi Gas-fired Steam Boilers— front view
Rated evaporation500kg/hr
Max. working pressure10kg/cm²
Max. efficiency90%
Time to steam4–5minutes

Highlights

Simple to run, day after day.

OT-500Gi integrates startup, monitoring and safety controls in a clear interface for varying loads and long production runs.

  1. 01Fast Startup

    Steam about 4–5 minutes after ignition.

  2. 02Saves space

    Compact once-through design, heating surface 8.0 m².

  3. 03Parallel Operation

    Run more or fewer units as load changes, and keep steam during maintenance.

  4. 04Colour touchscreen

    Touch control showing operating status and fault history.

  5. 05Optional economiser

    Boiler efficiency 88%, up to 90% with an economiser.

  6. 06Safety controls

    Safety valve 40 A, with full safety devices and controls.

Interface and details

OT-500Gi Specifications

The economizer recovers flue-gas heat to reduce fuel use. Actual savings depend on load and operating conditions.

SpecStandardWith economizer
Rated evaporation500 kg/hr
Actual evaporation415 kg/hr
Heat output269,500 kcal/hr
Efficiency88%90%
Fuel consumptionLNG 31.6 Nm³/hr
LPG 25.5 kg/hr
LNG 28.9 Nm³/hr
LPG 23.9 kg/hr
Power1.2 kW1.4 kW
Fuel inlet40 A
Flue size250 mm
Feedwater inlet20 A
Steam outlet32 A
Blowdown25 A
Safety valve40 A
Heating surface8.0 m²
DimensionsW1,064 × D1,527 × H2,215 mmW1,080 × D1,570 × H2,215 mm
Weight1,100 kg
Test conditions & notes
  1. Actual evaporation is based on feedwater at 15°C and saturated steam at 0.49 MPa.
  2. Boiler efficiency is calculated by the JIS B 8222-1993 heat-loss method. Efficiency tolerance: ±1%; combustion capacity tolerance: ±3.5%.
  3. Fuel consumption is calculated using the specified lower heating value. Actual gas heating value and supply pressure affect the result.
  4. Gas piping must maintain adequate pressure while the boiler and other equipment operate. Supply pressure range: 0.03–0.3 MPa.
  5. With an economizer, a feedwater temperature of at least 50°C is recommended.
  6. Specifications may change as products improve. Refer to the latest technical information from Chuang Ting for final selection.

Check whether OT-500Gi suits your site.

Share your connected equipment, steam demand, operating hours and site conditions so our engineers can confirm capacity and system configuration.

Call us · Kaohsiung headquarters+886-7-787-2258